Main range of product Altivar Easy 610product or component type Variable speed driveproduct specific application Fan, pump, compressor, conveyordevice short name ATV610variant Standard versionproduct destination Asynchronous motorsmounting mode Cabinet mountEMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m maximumIP degree of protection IP20type of cooling Forced convectionsupply frequency 50...60 Hz (+/-5 %)network number of phases 3 phases[Us] rated supply voltage 380...415 V (- 15...10 %)motor power kW 45 kW normal duty
37 kW heavy dutymotor power hp 60 hp normal duty
50 hp heavy dutyline current 92.9 A at 380 V normal duty
88.3 A at 415 V normal duty
80.5 A at 380 V heavy duty
75.8 A at 415 V heavy dutyprospective line Isc 22 kAapparent power 63.5 kVA at 415 V normal duty
54.5 kVA at 415 V heavy dutycontinuous output current 88 A at 4 kHz normal duty
75 A at 4 kHz heavy dutymaximum transient current 97 A during 60 s normal duty
112 A during 60 s heavy dutyasynchronous motor control profile Constant torque standard
Variable torque standard
Optimized torque modeoutput frequency 0.0001...0.5 kHznominal switching frequency 4 kHzswitching frequency 2...12 kHz adjustablenumber of preset speeds 16 preset speedscommunication port protocol Modbus serialoption card Slot A : communication card Profibus DP V1
Slot A : digital or analog I/O extension card
Slot A : relay output cardComplementary output voltage <= power supply voltagemotor slip compensation Adjustable
Automatic whatever the load
Can be suppressed
Not available in permanent magnet motor lawacceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s
S, U or customizedbraking to standstill By DC injectionprotection type Motor : thermal protection
Motor : motor phase break
Drive : thermal protection
Drive : overheating
Drive : overcurrent between output phases and earth
Drive : overload of output voltage
Drive : short-circuit protection
Drive : motor phase break
Drive : overvoltages on the DC bus
Drive : line supply overvoltage
Drive : line supply undervoltage
Drive : line supply phase loss
Drive : overspeed
Drive : break on the control circuitfrequency resolution Display unit : 0.1 Hz
Analog input : 0.012/50 Hzelectrical connection Line side, screw terminal : 35...50 mm²
Control, screw terminal : 0.5...1.5 mm²
Motor, screw terminal : 50 mm²connector type 1 RJ45 (on the remote graphic terminal) for Modbus serialphysical interface 2-wire RS 485 for Modbus serialtransmission frame RTU for Modbus serialtransmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serialtype of polarization No impedance for Modbus serialnumber of addresses 1...247 for Modbus serialmethod of access Slavesupply External supply for digital inputs : 24 V DC (limits : 19...30 V), <= 1.25 mA (overload and short-circuit protection)
Internal supply for reference potentiometer (1 to 10 kOhm) : 10.5 V DC +/- 5 %, <= 10 mA (overload and short-circuit protection)local signalling 1 LED red for presence of voltage
2 LEDs for local diagnostic
1 LED yellow for embedded communication status
2 LEDs dual colour for communication module statuswidth 226 mmheight 613 mm
706 mm with EMC platedepth 271 mmproduct weight 26.8 kganalogue input number 3analogue input type Software-configurable voltage AI1, AI2, AI3 : 0...10 V DC, impedance 30 kOhm, resolution 12 bits
Software-configurable current AI1, AI2, AI3 : 0...20 mA, impedance 250 Ohm, resolution 12 bits
Software-configurable temperature probe or water level sensor AI2, AI3discrete input number 6discrete input type Programmable as pulse input DI5, DI6 0...30 kHz : 24 V DC (limits : <= 30 V)
Programmable as logic input DI1...DI6 : 24 V DC (limits : <= 30 V), impedance 3.5 kOhminput compatibility Level 1 PLC conforming to EN/IEC 61131-2, logic input DI1...DI6
Level 1 PLC conforming to IEC 65A-68, pulse input DI5, DI6discrete input logic Positive logic (source) : DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) : DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source) : DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)analogue output number 2analogue output type Software-configurable current AQ1, AQ2 : 0...20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2 : 0...10 V DC,impedance 470 Ohm, resolution 10 bitssampling duration Analog input AI1, AI2, AI3 : 5 ms (+/- 0.1 ms)
Analog output AQ1, AQ2 : 10 ms (+/- 1 ms)
Discrete input DI1...DI6 : 2 ms (+/- 0.5 ms) configurable
Pulse input DI5, DI6 : 5 ms (+/- 1 ms) configurableaccuracy Analog input AI1, AI2, AI3 : +/- 0.6 % for a temperature variation 60 °C
Analog output AQ1, AQ2 : +/- 1 % for a temperature variation 60 °Clinearity error Analog input AI1, AI2, AI3 : +/- 0.15 % of maximum value
Analog output AQ1, AQ2 : +/- 0.2 %relay output number 3relay output type Configurable relay logic R1 : fault relay NO/NC, electrical durability 100000 cycles
Configurable relay logic R2 : sequence relay NO, electrical durability 100000 cycles
Configurable relay logic R3 : sequence relay NO, electrical durability 100000 cyclesrefresh time Relay output R1, R2, R3 : 5 ms (+/- 0.5 ms)minimum switching current Relay output R1, R2, R3 : 5 mA at 24 V DCmaximum switching current Relay output R1, R2, R3 on resistive load (cos phi = 1 : 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load (cos phi = 1 : 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 A at 30 V DCisolation Between power and control terminalsinsulation resistance > 1 mOhm at 500 V DC for 1 minute to earthEnvironment noise level 75 dB conforming to 86/188/EECpower dissipation in W 1000 W (forced convection) at 380 V, switching frequency 4 kHz
121 W (natural convection) at 380 V, switching frequency 4 kHzvolume of cooling air 240 m3/hoperating position Vertical +/- 10 degreeelectromagnetic compatibility 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6pollution degree 2 conforming to EN/IEC 61800-5-1vibration resistance 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6shock resistance 15 gn during 11 ms conforming to IEC 60068-2-27relative humidity 5...95 % without condensation conforming to IEC 60068-2-3ambient air temperature for operation -15...45 °C without derating
45...60 °C with derating factorambient air temperature for storage -40...70 °Coperating altitude 1000...4800 m with current derating 1 % per 100 m
<= 1000 m without deratingenvironmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3standards EN/IEC 61800-3
EN/IEC 61800-3 environment 2 category C3
EN/IEC 61800-5-1
IEC 60721-3product certifications REACHmarking CEOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions -
เอกสารและดาวน์โหลด
ภาษาCatalogueขนาดเพิ่มในเอกสารของฉันCatalog Altivar Easy 610 (รุ่น 5.0)User guide2) ATV610 Installation manual (รุ่น 06.1)ATV610 PROFIBUS DP Manual - VW3A3607 (รุ่น 01)3) ATV610 Programming Manual (รุ่น 04)1) ATV610 Getting started (รุ่น 04)ATV610 Modbus manual (รุ่น 01)CertificateATV610 EU DECLARATION (รุ่น 1.0)ATV6XX-BACNET-CERTIFICATE (รุ่น 1.0)End of Life InformationALTIVAR 610 - Size 1 - 0.75 to 7.5kW - 3PH - 380/415V, Product End-of-Life Instructions (รุ่น 2.0)ALTIVAR 610 -Size 4 - 3PH/ 30 to 45KW 400V - 3PH - IP20, Product End-of-Life Instructions (รุ่น 1.0)EU RoHS DeclarationProduct Environmental ProfileALTIVAR 610 -Size 4 - 3PH/ 30 to 45KW 400V - 3PH - IP20, Product Environmental Profile (รุ่น 1.0)ALTIVAR 610 - Size 1 - 0.75 to 7.5kW - 3PH - 380/415V, Product Environmental Profile (รุ่น 2.0)Instruction Sheet: China RoHS - Hazardous Substances Table (รุ่น 01)REACh Declaration